Search
Total
49350 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-4941 | 2 Apple, Vmware | 4 Mac Os X, Esxi, Fusion and 1 more | 2022-02-03 | 6.0 MEDIUM | 8.8 HIGH |
| VMware ESXi (6.0 before ESXi600-201711101-SG, 5.5 ESXi550-201709101-SG), Workstation (12.x before 12.5.8), and Fusion (8.x before 8.5.9) contain a vulnerability that could allow an authenticated VNC session to cause a stack overflow via a specific set of VNC packets. Successful exploitation of this issue could result in remote code execution in a virtual machine via the authenticated VNC session. Note: In order for exploitation to be possible in ESXi, VNC must be manually enabled in a virtual machine's .vmx configuration file. In addition, ESXi must be configured to allow VNC traffic through the built-in firewall. | |||||
| CVE-2017-4933 | 2 Apple, Vmware | 4 Mac Os X, Esxi, Fusion and 1 more | 2022-02-03 | 6.0 MEDIUM | 8.8 HIGH |
| VMware ESXi (6.5 before ESXi650-201710401-BG), Workstation (12.x before 12.5.8), and Fusion (8.x before 8.5.9) contain a vulnerability that could allow an authenticated VNC session to cause a heap overflow via a specific set of VNC packets resulting in heap corruption. Successful exploitation of this issue could result in remote code execution in a virtual machine via the authenticated VNC session. Note: In order for exploitation to be possible in ESXi, VNC must be manually enabled in a virtual machine's .vmx configuration file. In addition, ESXi must be configured to allow VNC traffic through the built-in firewall. | |||||
| CVE-2017-4924 | 1 Vmware | 3 Esxi, Fusion, Workstation Pro | 2022-02-03 | 7.2 HIGH | 8.8 HIGH |
| VMware ESXi (ESXi 6.5 without patch ESXi650-201707101-SG), Workstation (12.x before 12.5.7) and Fusion (8.x before 8.5.8) contain an out-of-bounds write vulnerability in SVGA device. This issue may allow a guest to execute code on the host. | |||||
| CVE-2017-4903 | 2 Apple, Vmware | 6 Mac Os X, Esxi, Fusion and 3 more | 2022-02-03 | 7.2 HIGH | 8.8 HIGH |
| VMware ESXi 6.5 without patch ESXi650-201703410-SG, 6.0 U3 without patch ESXi600-201703401-SG, 6.0 U2 without patch ESXi600-201703403-SG, 6.0 U1 without patch ESXi600-201703402-SG, and 5.5 without patch ESXi550-201703401-SG; Workstation Pro / Player 12.x prior to 12.5.5; and Fusion Pro / Fusion 8.x prior to 8.5.6 have an uninitialized stack memory usage in SVGA. This issue may allow a guest to execute code on the host. | |||||
| CVE-2021-22818 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2) | |||||
| CVE-2021-22821 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2022-02-03 | 5.0 MEDIUM | 8.6 HIGH |
| A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2) | |||||
| CVE-2017-4902 | 2 Apple, Vmware | 6 Mac Os X, Esxi, Fusion and 3 more | 2022-02-03 | 7.2 HIGH | 8.8 HIGH |
| VMware ESXi 6.5 without patch ESXi650-201703410-SG and 5.5 without patch ESXi550-201703401-SG; Workstation Pro / Player 12.x prior to 12.5.5; and Fusion Pro / Fusion 8.x prior to 8.5.6 have a Heap Buffer Overflow in SVGA. This issue may allow a guest to execute code on the host. | |||||
| CVE-2021-40340 | 1 Hitachi | 1 Linkone | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| Information Exposure vulnerability in Hitachi Energy LinkOne application, due to a misconfiguration in the ASP server exposes server and ASP.net information, an attacker that manages to exploit this vulnerability can use the exposed information as a reconnaissance for further exploitation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25; 3.26. | |||||
| CVE-2021-40339 | 1 Hitachi | 1 Linkone | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| Configuration vulnerability in Hitachi Energy LinkOne application due to the lack of HTTP Headers, allows an attacker that manages to exploit this vulnerability to retrieve sensitive information. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25; 3.26. | |||||
| CVE-2021-27654 | 1 Pega | 1 Infinity | 2022-02-03 | 4.6 MEDIUM | 7.8 HIGH |
| Forgotten password reset functionality for local accounts can be used to bypass local authentication checks. | |||||
| CVE-2021-22825 | 1 Schneider-electric | 4 Rack Power Distribution Unit With Network Management Card 2, Rack Power Distribution Unit With Network Management Card 2 Firmware, Rack Power Distribution Unit With Network Management Card 3 and 1 more | 2022-02-03 | 6.0 MEDIUM | 8.0 HIGH |
| A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier) | |||||
| CVE-2021-22713 | 1 Schneider-electric | 21 Ion7650 Firmware, Powerlogic Ion7300, Powerlogic Ion7300 Firmware and 18 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot. | |||||
| CVE-2021-22703 | 1 Schneider-electric | 20 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion7650 and 17 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device. | |||||
| CVE-2021-22702 | 1 Schneider-electric | 24 Powerlogic Ion7300, Powerlogic Ion7300 Firmware, Powerlogic Ion7400 and 21 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device. | |||||
| CVE-2021-22699 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP. | |||||
| CVE-2020-7566 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 4.3 MEDIUM | 7.3 HIGH |
| A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. | |||||
| CVE-2020-7565 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 4.3 MEDIUM | 7.3 HIGH |
| A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. | |||||
| CVE-2020-7511 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to acquire a password by brute force. | |||||
| CVE-2020-7510 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-200: Information Exposure vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow attacker to obtain private keys. | |||||
| CVE-2020-7488 | 1 Schneider-electric | 11 Ecostruxure Machine Expert, Modicon M218, Modicon M218 Firmware and 8 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. | |||||
| CVE-2019-6851 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol. | |||||
| CVE-2019-6845 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. | |||||
| CVE-2022-23968 | 1 Xerox | 21 Versalink B400, Versalink B405, Versalink B600 and 18 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| Xerox VersaLink devices on specific versions of firmware before 2022-01-26 allow remote attackers to brick the device via a crafted TIFF file in an unauthenticated HTTP POST request. There is a permanent denial of service because image parsing causes a reboot, but image parsing is restarted as soon as the boot process finishes. However, this boot loop can be resolved by a field technician. The TIFF file must have an incomplete Image Directory. Affected firmware versions include xx.42.01 and xx.50.61. NOTE: the 2022-01-24 NeoSmart article included "believed to affect all previous and later versions as of the date of this posting" but a 2022-01-26 vendor statement reports "the latest versions of firmware are not vulnerable to this issue." | |||||
| CVE-2022-21944 | 2 Opensuse, Suse | 2 Factory Watchman, Suse Linux Enterprise Server | 2022-02-03 | 7.2 HIGH | 7.8 HIGH |
| A UNIX Symbolic Link (Symlink) Following vulnerability in the systemd service file for watchman of openSUSE Backports SLE-15-SP3, Factory allows local attackers to escalate to root. This issue affects: openSUSE Backports SLE-15-SP3 watchman versions prior to 4.9.0. openSUSE Factory watchman versions prior to 4.9.0-9.1. | |||||
| CVE-2019-6859 | 1 Schneider-electric | 20 140 Cpu6x, 140 Cpu6x Firmware, 140 Noc 77101 and 17 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network. | |||||
| CVE-2019-6857 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP. | |||||
| CVE-2019-6856 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP. | |||||
| CVE-2022-24266 | 1 Cuppacms | 1 Cuppacms | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| Cuppa CMS v1.0 was discovered to contain a SQL injection vulnerability in /administrator/components/table_manager/ via the order_by parameter. | |||||
| CVE-2022-24265 | 1 Cuppacms | 1 Cuppacms | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| Cuppa CMS v1.0 was discovered to contain a SQL injection vulnerability in /administrator/components/menu/ via the path=component/menu/&menu_filter=3 parameter. | |||||
| CVE-2022-24264 | 1 Cuppacms | 1 Cuppacms | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| Cuppa CMS v1.0 was discovered to contain a SQL injection vulnerability in /administrator/components/table_manager/ via the search_word parameter. | |||||
| CVE-2021-41766 | 1 Apache | 1 Karaf | 2022-02-03 | 6.8 MEDIUM | 8.1 HIGH |
| Apache Karaf allows monitoring of applications and the Java runtime by using the Java Management Extensions (JMX). JMX is a Java RMI based technology that relies on Java serialized objects for client server communication. Whereas the default JMX implementation is hardened against unauthenticated deserialization attacks, the implementation used by Apache Karaf is not protected against this kind of attack. The impact of Java deserialization vulnerabilities strongly depends on the classes that are available within the targets class path. Generally speaking, deserialization of untrusted data does always represent a high security risk and should be prevented. The risk is low as, by default, Karaf uses a limited set of classes in the JMX server class path. It depends of system scoped classes (e.g. jar in the lib folder). | |||||
| CVE-2018-7794 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP. | |||||
| CVE-2018-7789 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames. | |||||
| CVE-2019-6828 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus. | |||||
| CVE-2018-7792 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table. | |||||
| CVE-2019-6820 | 1 Schneider-electric | 24 Atv Imc Drive Controller, Atv Imc Drive Controller Firmware, Modicon Lmc058 and 21 more | 2022-02-03 | 6.4 MEDIUM | 8.2 HIGH |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2 | |||||
| CVE-2019-6813 | 1 Schneider-electric | 4 Bmxnor0200h, Bmxnor0200h Firmware, Modicon M340 and 1 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device. | |||||
| CVE-2019-6809 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller. | |||||
| CVE-2019-6807 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. | |||||
| CVE-2019-6829 | 1 Schneider-electric | 4 Modicon M340, Modicon M340 Firmware, Modicon M580 and 1 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus. | |||||
| CVE-2019-6806 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. | |||||
| CVE-2016-4529 | 1 Schneider-electric | 3 M171, M172, Somachine Hvac Firmware | 2022-02-03 | 7.5 HIGH | 7.3 HIGH |
| An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag. | |||||
| CVE-2020-7486 | 1 Schneider-electric | 12 Tricon Tcm 4351, Tricon Tcm 4351 Firmware, Tricon Tcm 4351a and 9 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| **VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior. | |||||
| CVE-2019-6826 | 1 Schneider-electric | 1 Somachine Hvac | 2022-02-03 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product. | |||||
| CVE-2018-7857 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. | |||||
| CVE-2018-7856 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus. | |||||
| CVE-2018-7855 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus | |||||
| CVE-2018-7854 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. | |||||
| CVE-2018-7853 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus | |||||
| CVE-2018-7852 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |