| CVE-2023-46245 | 1 Kimai | 1 Kimai | 2024-01-12 | N/A | 7.2 HIGH |
| Kimai is a web-based multi-user time-tracking application. Versions prior to 2.1.0 are vulnerable to a Server-Side Template Injection (SSTI) which can be escalated to Remote Code Execution (RCE). The vulnerability arises when a malicious user uploads a specially crafted Twig file, exploiting the software's PDF and HTML rendering functionalities. Version 2.1.0 enables security measures for custom Twig templates. | |||||
| CVE-2023-49961 | 1 Wallix | 2 Bastion, Bastion Access Manager | 2024-01-12 | N/A | 7.5 HIGH |
| WALLIX Bastion 7.x, 8.x, 9.x and 10.x and WALLIX Access Manager 3.x and 4.x have Incorrect Access Control which can lead to sensitive data exposure. | |||||
| CVE-2023-29051 | 1 Open-xchange | 1 Ox App Suite | 2024-01-12 | N/A | 8.1 HIGH |
| User-defined OXMF templates could be used to access a limited part of the internal OX App Suite Java API. The existing switch to disable the feature by default was not effective in this case. Unauthorized users could discover and modify application state, including objects related to other users and contexts. We now make sure that the switch to disable user-generated templates by default works as intended and will remove the feature in future generations of the product. No publicly available exploits are known. | |||||
| CVE-2023-46813 | 1 Linux | 1 Linux Kernel | 2024-01-11 | N/A | 7.0 HIGH |
| An issue was discovered in the Linux kernel before 6.5.9, exploitable by local users with userspace access to MMIO registers. Incorrect access checking in the #VC handler and instruction emulation of the SEV-ES emulation of MMIO accesses could lead to arbitrary write access to kernel memory (and thus privilege escalation). This depends on a race condition through which userspace can replace an instruction before the #VC handler reads it. | |||||
| CVE-2023-37921 | 1 Tonybybell | 1 Gtkwave | 2024-01-11 | N/A | 7.8 HIGH |
| Multiple arbitrary write vulnerabilities exist in the VCD sorted bsearch functionality of GTKWave 3.3.115. A specially crafted .vcd file can lead to arbitrary code execution. A victim would need to open a malicious file to trigger these vulnerabilities.This vulnerability concerns the arbitrary write when triggered via the vcd2vzt conversion utility. | |||||
| CVE-2023-37922 | 1 Tonybybell | 1 Gtkwave | 2024-01-11 | N/A | 7.8 HIGH |
| Multiple arbitrary write vulnerabilities exist in the VCD sorted bsearch functionality of GTKWave 3.3.115. A specially crafted .vcd file can lead to arbitrary code execution. A victim would need to open a malicious file to trigger these vulnerabilities.This vulnerability concerns the arbitrary write when triggered via the vcd2lxt2 conversion utility. | |||||
| CVE-2023-37923 | 1 Tonybybell | 1 Gtkwave | 2024-01-11 | N/A | 7.8 HIGH |
| Multiple arbitrary write vulnerabilities exist in the VCD sorted bsearch functionality of GTKWave 3.3.115. A specially crafted .vcd file can lead to arbitrary code execution. A victim would need to open a malicious file to trigger these vulnerabilities.This vulnerability concerns the arbitrary write when triggered via the vcd2lxt conversion utility. | |||||
| CVE-2023-47140 | 1 Ibm | 1 Cics Transaction Gateway | 2024-01-11 | N/A | 8.1 HIGH |
| IBM CICS Transaction Gateway 9.3 could allow a user to transfer or view files due to improper access controls. IBM X-Force ID: 270259. | |||||
| CVE-2023-50082 | 1 Pbootcms | 1 Pbootcms | 2024-01-10 | N/A | 7.5 HIGH |
| Aoyun Technology pbootcms V3.1.2 is vulnerable to Incorrect Access Control, allows remote attackers to gain sensitive information via session leakage allows a user to avoid logging into the backend management platform. | |||||
| CVE-2023-47882 | 1 Kamivision | 1 Yi Iot | 2024-01-09 | N/A | 7.1 HIGH |
| The Kami Vision YI IoT com.yunyi.smartcamera application through 4.1.9_20231127 for Android allows a remote attacker to execute arbitrary JavaScript code via an implicit intent to the com.ants360.yicamera.activity.WebViewActivity component. | |||||
| CVE-2023-50341 | 1 Hcltech | 1 Dryice Myxalytics | 2024-01-09 | N/A | 7.5 HIGH |
| HCL DRYiCE MyXalytics is impacted by Improper Access Control (Obsolete web pages) vulnerability. Discovery of outdated and accessible web pages, reflects a "Missing Access Control" vulnerability, which could lead to inadvertent exposure of sensitive information and/or exposing a vulnerable endpoint. | |||||
| CVE-2023-39909 | 1 Ericsson | 1 Network Manager | 2024-01-08 | N/A | 8.8 HIGH |
| Ericsson Network Manager before 23.2 mishandles Access Control and thus unauthenticated low-privilege users can access the NCM application. | |||||
| CVE-2023-7193 | 1 Mtab | 1 Bookmark | 2024-01-05 | N/A | 8.1 HIGH |
| A vulnerability was found in MTab Bookmark up to 1.2.6 and classified as critical. This issue affects some unknown processing of the file public/install.php of the component Installation. The manipulation leads to improper access controls. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-249395. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2023-23570 | 1 Gallagher | 1 Command Centre | 2024-01-05 | N/A | 8.1 HIGH |
| Client-Side enforcement of Server-Side security for the Command Centre server could be bypassed and lead to invalid configuration with undefined behavior. This issue affects: Gallagher Command Centre 8.90 prior to vEL8.90.1620 (MR2), all versions of 8.80 and prior. | |||||
| CVE-2023-49002 | 1 Xenomtechnologies | 1 Phone Dialer-voice Call Dialer | 2024-01-05 | N/A | 7.5 HIGH |
| An issue in Xenom Technologies (sinous) Phone Dialer-voice Call Dialer v.1.2.5 allows an attacker to bypass intended access restrictions via interaction with com.funprime.calldialer.ui.activities.OutgoingActivity. | |||||
| CVE-2023-51767 | 3 Fedoraproject, Openssh, Redhat | 3 Fedora, Openssh, Enterprise Linux | 2024-01-04 | N/A | 7.0 HIGH |
| OpenSSH through 9.6, when common types of DRAM are used, might allow row hammer attacks (for authentication bypass) because the integer value of authenticated in mm_answer_authpassword does not resist flips of a single bit. NOTE: this is applicable to a certain threat model of attacker-victim co-location in which the attacker has user privileges. | |||||
| CVE-2023-49938 | 1 Schedmd | 1 Slurm | 2024-01-03 | N/A | 8.2 HIGH |
| An issue was discovered in SchedMD Slurm 22.05.x and 23.02.x. There is Incorrect Access Control: an attacker can modified their extended group list that is used with the sbcast subsystem, and open files with an unauthorized set of extended groups. The fixed versions are 22.05.11 and 23.02.7. | |||||
| CVE-2023-51661 | 1 Wasmer | 1 Wasmer | 2024-01-03 | N/A | 8.6 HIGH |
| Wasmer is a WebAssembly runtime that enables containers to run anywhere: from Desktop to the Cloud, Edge and even the browser. Wasm programs can access the filesystem outside of the sandbox. Service providers running untrusted Wasm code on Wasmer can unexpectedly expose the host filesystem. This vulnerability has been patched in version 4.2.4. | |||||
| CVE-2023-7025 | 1 Kylinos | 1 Hedron-domain-hook | 2024-01-02 | N/A | 7.8 HIGH |
| A vulnerability was found in KylinSoft hedron-domain-hook up to 3.8.0.12-0k0.5. It has been declared as critical. This vulnerability affects the function init_kcm of the component DBus Handler. The manipulation leads to improper access controls. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. VDB-248578 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2023-2585 | 1 Redhat | 6 Enterprise Linux, Openshift Container Platform, Openshift Container Platform For Ibm Z and 3 more | 2024-01-02 | N/A | 8.1 HIGH |
| Keycloak's device authorization grant does not correctly validate the device code and client ID. An attacker client could abuse the missing validation to spoof a client consent request and trick an authorization admin into granting consent to a malicious OAuth client or possible unauthorized access to an existing OAuth client. | |||||
| CVE-2023-5764 | 2 Fedoraproject, Redhat | 7 Extra Packages For Enterprise Linux, Fedora, Ansible and 4 more | 2024-01-01 | N/A | 7.8 HIGH |
| A template injection flaw was found in Ansible where a user's controller internal templating operations may remove the unsafe designation from template data. This issue could allow an attacker to use a specially crafted file to introduce code injection when supplying templating data. | |||||
| CVE-2020-16969 | 1 Microsoft | 1 Exchange Server | 2023-12-31 | 4.3 MEDIUM | 7.1 HIGH |
| <p>An information disclosure vulnerability exists in how Microsoft Exchange validates tokens when handling certain messages. An attacker who successfully exploited the vulnerability could use this to gain further information from a user.</p> <p>To exploit the vulnerability, an attacker could include specially crafted OWA messages that could be loaded, without warning or filtering, from the attacker-controlled URL. This callback vector provides an information disclosure tactic used in web beacons and other types of tracking systems.</p> <p>The security update corrects the way that Exchange handles these token validations.</p> | |||||
| CVE-2021-36934 | 1 Microsoft | 1 Windows 10 | 2023-12-28 | 4.6 MEDIUM | 7.8 HIGH |
| <p>An elevation of privilege vulnerability exists because of overly permissive Access Control Lists (ACLs) on multiple system files, including the Security Accounts Manager (SAM) database. An attacker who successfully exploited this vulnerability could run arbitrary code with SYSTEM privileges. An attacker could then install programs; view, change, or delete data; or create new accounts with full user rights.</p> <p>An attacker must have the ability to execute code on a victim system to exploit this vulnerability.</p> <p>After installing this security update, you <em>must</em> manually delete all shadow copies of system files, including the SAM database, to fully mitigate this vulnerabilty. <strong>Simply installing this security update will not fully mitigate this vulnerability.</strong> See <a href="https://support.microsoft.com/topic/1ceaa637-aaa3-4b58-a48b-baf72a2fa9e7">KB5005357- Delete Volume Shadow Copies</a>.</p> | |||||
| CVE-2021-26431 | 1 Microsoft | 2 Windows 10, Windows Server 2016 | 2023-12-28 | 4.6 MEDIUM | 7.8 HIGH |
| Windows Recovery Environment Agent Elevation of Privilege Vulnerability | |||||
| CVE-2021-36942 | 1 Microsoft | 4 Windows Server 2008, Windows Server 2012, Windows Server 2016 and 1 more | 2023-12-28 | 5.0 MEDIUM | 7.5 HIGH |
| Windows LSA Spoofing Vulnerability | |||||
| CVE-2023-46686 | 1 Gallagher | 1 Command Centre | 2023-12-28 | N/A | 7.1 HIGH |
| A reliance on untrusted inputs in a security decision could be exploited by a privileged user to configure the Gallagher Command Centre Diagnostics Service to use less secure communication protocols. This issue affects: Gallagher Diagnostics Service prior to v1.3.0 (distributed in 9.00.1507(MR1)). | |||||
| CVE-2022-3697 | 1 Redhat | 2 Ansible, Ansible Collection | 2023-12-28 | N/A | 7.5 HIGH |
| A flaw was found in Ansible in the amazon.aws collection when using the tower_callback parameter from the amazon.aws.ec2_instance module. This flaw allows an attacker to take advantage of this issue as the module is handling the parameter insecurely, leading to the password leaking in the logs. | |||||
| CVE-2021-42321 | 1 Microsoft | 1 Exchange Server | 2023-12-28 | 6.5 MEDIUM | 8.8 HIGH |
| Microsoft Exchange Server Remote Code Execution Vulnerability | |||||
| CVE-2021-42292 | 1 Microsoft | 4 365 Apps, Excel, Office and 1 more | 2023-12-28 | 6.8 MEDIUM | 7.8 HIGH |
| Microsoft Excel Security Feature Bypass Vulnerability | |||||
| CVE-2023-3655 | 1 Cashit | 1 Cashit\! | 2023-12-28 | N/A | 7.5 HIGH |
| cashIT! - serving solutions. Devices from "PoS/ Dienstleistung, Entwicklung & Vertrieb GmbH" to 03.A06rks 2023.02.37 are affected by a dangerous methods, that allows to leak the database (system settings, user accounts,...). This vulnerability can be triggered by an HTTP endpoint exposed to the network. | |||||
| CVE-2023-44285 | 1 Dell | 12 Apex Protection Storage, Dd3300, Dd6400 and 9 more | 2023-12-27 | N/A | 7.8 HIGH |
| Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege. | |||||
| CVE-2022-3496 | 1 Oretnom23 | 1 Human Resource Management System | 2023-12-26 | N/A | 8.8 HIGH |
| A vulnerability was found in SourceCodester Human Resource Management System 1.0 and classified as critical. This issue affects some unknown processing of the file employeeadd.php of the component Admin Panel. The manipulation leads to improper access controls. The attack may be initiated remotely. The identifier VDB-210785 was assigned to this vulnerability. | |||||
| CVE-2021-41617 | 5 Fedoraproject, Netapp, Openbsd and 2 more | 14 Fedora, Active Iq Unified Manager, Aff 500f and 11 more | 2023-12-26 | 4.4 MEDIUM | 7.0 HIGH |
| sshd in OpenSSH 6.2 through 8.x before 8.8, when certain non-default configurations are used, allows privilege escalation because supplemental groups are not initialized as expected. Helper programs for AuthorizedKeysCommand and AuthorizedPrincipalsCommand may run with privileges associated with group memberships of the sshd process, if the configuration specifies running the command as a different user. | |||||
| CVE-2021-41133 | 3 Debian, Fedoraproject, Flatpak | 3 Debian Linux, Fedora, Flatpak | 2023-12-23 | 4.6 MEDIUM | 7.8 HIGH |
| Flatpak is a system for building, distributing, and running sandboxed desktop applications on Linux. In versions prior to 1.10.4 and 1.12.0, Flatpak apps with direct access to AF_UNIX sockets such as those used by Wayland, Pipewire or pipewire-pulse can trick portals and other host-OS services into treating the Flatpak app as though it was an ordinary, non-sandboxed host-OS process. They can do this by manipulating the VFS using recent mount-related syscalls that are not blocked by Flatpak's denylist seccomp filter, in order to substitute a crafted `/.flatpak-info` or make that file disappear entirely. Flatpak apps that act as clients for AF_UNIX sockets such as those used by Wayland, Pipewire or pipewire-pulse can escalate the privileges that the corresponding services will believe the Flatpak app has. Note that protocols that operate entirely over the D-Bus session bus (user bus), system bus or accessibility bus are not affected by this. This is due to the use of a proxy process `xdg-dbus-proxy`, whose VFS cannot be manipulated by the Flatpak app, when interacting with these buses. Patches exist for versions 1.10.4 and 1.12.0, and as of time of publication, a patch for version 1.8.2 is being planned. There are no workarounds aside from upgrading to a patched version. | |||||
| CVE-2023-32230 | 1 Bosch | 7 Monitor Wall, Video Recording Manager, Video Streaming Gateway and 4 more | 2023-12-22 | N/A | 7.5 HIGH |
| An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. | |||||
| CVE-2023-45774 | 1 Google | 1 Android | 2023-12-22 | N/A | 7.8 HIGH |
| In fixUpIncomingShortcutInfo of ShortcutService.java, there is a possible way to view another user's image due to a confused deputy. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. | |||||
| CVE-2023-4809 | 1 Freebsd | 1 Freebsd | 2023-12-21 | N/A | 7.5 HIGH |
| In pf packet processing with a 'scrub fragment reassemble' rule, a packet containing multiple IPv6 fragment headers would be reassembled, and then immediately processed. That is, a packet with multiple fragment extension headers would not be recognized as the correct ultimate payload. Instead a packet with multiple IPv6 fragment headers would unexpectedly be interpreted as a fragmented packet, rather than as whatever the real payload is. As a result, IPv6 fragments may bypass pf firewall rules written on the assumption all fragments have been reassembled and, as a result, be forwarded or processed by the host. | |||||
| CVE-2022-30945 | 1 Jenkins | 1 Pipeline\ | 2023-12-21 | 6.8 MEDIUM | 8.5 HIGH |
| Jenkins Pipeline: Groovy Plugin 2689.v434009a_31b_f1 and earlier allows loading any Groovy source files on the classpath of Jenkins and Jenkins plugins in sandboxed pipelines. | |||||
| CVE-2022-22934 | 1 Saltstack | 1 Salt | 2023-12-21 | 5.8 MEDIUM | 8.8 HIGH |
| An issue was discovered in SaltStack Salt in versions before 3002.8, 3003.4, 3004.1. Salt Masters do not sign pillar data with the minion’s public key, which can result in attackers substituting arbitrary pillar data. | |||||
| CVE-2022-47909 | 1 Tribe29 | 1 Checkmk | 2023-12-21 | N/A | 7.8 HIGH |
| Livestatus Query Language (LQL) injection in the AuthUser HTTP query header of Tribe29's Checkmk <= 2.1.0p11, Checkmk <= 2.0.0p28, and all versions of Checkmk 1.6.0 (EOL) allows an attacker to perform direct queries to the application's core from localhost. | |||||
| CVE-2023-3904 | 1 Gitlab | 1 Gitlab | 2023-12-19 | N/A | 7.5 HIGH |
| An issue has been discovered in GitLab EE affecting all versions starting before 16.4.4, all versions starting from 16.5 before 16.5.4, all versions starting from 16.6 before 16.6.2. It was possible to overflow the time spent on an issue that altered the details shown in the issue boards. | |||||
| CVE-2023-3517 | 1 Hitachi | 1 Pentaho Data Integration And Analytics | 2023-12-18 | N/A | 8.8 HIGH |
| Hitachi Vantara Pentaho Data Integration & Analytics versions before 9.5.0.1 and 9.3.0.5, including 8.3.x does not restrict JNDI identifiers during the creation of XActions, allowing control of system level data sources. | |||||
| CVE-2023-47323 | 1 Silverpeas | 1 Silverpeas | 2023-12-15 | N/A | 7.5 HIGH |
| The notification/messaging feature of Silverpeas Core 6.3.1 does not enforce access control on the ID parameter. This allows an attacker to read all messages sent between other users; including those sent only to administrators. | |||||
| CVE-2023-47320 | 1 Silverpeas | 1 Silverpeas | 2023-12-15 | N/A | 8.1 HIGH |
| Silverpeas Core 6.3.1 is vulnerable to Incorrect Access Control. An attacker with low privileges is able to execute the administrator-only function of putting the application in "Maintenance Mode" due to broken access control. This makes the application unavailable to all users. This affects Silverpeas Core 6.3.1 and below. | |||||
| CVE-2023-1260 | 2 Kubernetes, Redhat | 2 Kube-apiserver, Openshift Container Platform | 2023-12-15 | N/A | 8.0 HIGH |
| An authentication bypass vulnerability was discovered in kube-apiserver. This issue could allow a remote, authenticated attacker who has been given permissions "update, patch" the "pods/ephemeralcontainers" subresource beyond what the default is. They would then need to create a new pod or patch one that they already have access to. This might allow evasion of SCC admission restrictions, thereby gaining control of a privileged pod. | |||||
| CVE-2022-48615 | 1 Huawei | 2 Ar617vw, Ar617vw Firmware | 2023-12-15 | N/A | 7.1 HIGH |
| An improper access control vulnerability exists in a Huawei datacom product. Attackers can exploit this vulnerability to obtain partial device information. | |||||
| CVE-2023-46389 | 1 Loytec | 4 Linx-151, Linx-151 Firmware, Linx-212 and 1 more | 2023-12-14 | N/A | 7.5 HIGH |
| LOYTEC electronics GmbH LINX-212 firmware 6.2.4 and LINX-151 Firmware 7.2.4 are vulnerable to Incorrect Access Control via registry.xml file. This vulnerability allows remote attackers to disclose sensitive information on LINX configuration. | |||||
| CVE-2023-46387 | 1 Loytec | 4 Linx-151, Linx-151 Firmware, Linx-212 and 1 more | 2023-12-14 | N/A | 7.5 HIGH |
| LOYTEC electronics GmbH LINX-212 firmware 6.2.4 and LINX-151 firmware 7.2.4 are vulnerable to Incorrect Access Control via dpal_config.zml file. This vulnerability allows remote attackers to disclose sensitive information on Loytec device data point configuration. | |||||
| CVE-2023-42581 | 1 Samsung | 1 Galaxy Store | 2023-12-12 | N/A | 7.5 HIGH |
| Improper URL validation from InstantPlay deeplink in Galaxy Store prior to version 4.5.64.4 allows attackers to execute JavaScript API to access data. | |||||
| CVE-2023-49246 | 1 Huawei | 2 Emui, Harmonyos | 2023-12-12 | N/A | 7.5 HIGH |
| Unauthorized access vulnerability in the card management module. Successful exploitation of this vulnerability may affect service confidentiality. | |||||