Vulnerabilities (CVE)

Filtered by vendor Vivotek Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-14457 1 Vivotek 1 Camera 2021-07-21 7.5 HIGH 9.8 CRITICAL
VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header.
CVE-2018-14494 1 Vivotek 2 Fd8136, Fd8136 Firmware 2020-08-24 10.0 HIGH 9.8 CRITICAL
** DISPUTED ** Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware.
CVE-2018-14495 1 Vivotek 2 Fd8136, Fd8136 Firmware 2020-08-24 10.0 HIGH 9.8 CRITICAL
** DISPUTED ** Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance.
CVE-2018-14496 1 Vivotek 2 Fd8136, Fd8136 Firmware 2020-08-24 7.5 HIGH 9.8 CRITICAL
** DISPUTED ** Vivotek FD8136 devices allow remote memory corruption and remote code execution because of a stack-based buffer overflow, related to sprintf, vlocal_buff_4326, and set_getparam.cgi. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance.
CVE-2019-10256 1 Vivotek 1 Camera 2020-08-24 7.5 HIGH 9.8 CRITICAL
An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found.
CVE-2013-1595 1 Vivotek 2 Pt7135, Pt7135 Firmware 2020-01-27 7.5 HIGH 9.8 CRITICAL
A Buffer Overflow vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via a specially crafted packet in the Authorization header field sent to the RTSP service, which could let a remote malicious user execute arbitrary code or cause a Denial of Service.
CVE-2017-9828 1 Vivotek 6 Network Camera Fd8164, Network Camera Fd8164 Firmware, Network Camera Fd816ba and 3 more 2019-10-03 10.0 HIGH 9.8 CRITICAL
'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root via a crafted HTTP request. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. An attack uses shell metacharacters in the senderemail parameter.