Filtered by vendor Codesys
Subscribe
Search
Total
18 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-34584 | 1 Codesys | 1 Codesys | 2022-07-28 | 6.4 MEDIUM | 9.1 CRITICAL |
| Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22. | |||||
| CVE-2021-30192 | 1 Codesys | 1 V2 Web Server | 2022-07-12 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check. | |||||
| CVE-2022-31806 | 1 Codesys | 2 Plcwinnt, Runtime Toolkit | 2022-07-07 | 6.8 MEDIUM | 9.8 CRITICAL |
| In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller. | |||||
| CVE-2022-31802 | 1 Codesys | 1 Gateway | 2022-07-01 | 7.5 HIGH | 9.8 CRITICAL |
| In CODESYS Gateway Server V2 for versions prior to V2.3.9.38 only a part of the the specified password is been compared to the real CODESYS Gateway password. An attacker may perform authentication by specifying a small password that matches the corresponding part of the longer real CODESYS Gateway password. | |||||
| CVE-2021-30190 | 1 Codesys | 1 V2 Web Server | 2022-05-03 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. | |||||
| CVE-2019-13548 | 1 Codesys | 13 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 10 more | 2021-10-28 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. | |||||
| CVE-2021-33485 | 1 Codesys | 7 Control, Control Rte, Control Runtime System Toolkit and 4 more | 2021-08-17 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. | |||||
| CVE-2021-30188 | 1 Codesys | 1 V2 Runtime System Sp | 2021-05-26 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow. | |||||
| CVE-2021-30189 | 1 Codesys | 1 V2 Web Server | 2021-05-26 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow. | |||||
| CVE-2021-30193 | 1 Codesys | 1 V2 Web Server | 2021-05-26 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write. | |||||
| CVE-2021-30194 | 1 Codesys | 1 V2 Web Server | 2021-05-25 | 6.4 MEDIUM | 9.1 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Read. | |||||
| CVE-2019-9010 | 1 Codesys | 10 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 7 more | 2020-08-24 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System. | |||||
| CVE-2020-10245 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2020-04-01 | 10.0 HIGH | 9.8 CRITICAL |
| CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. | |||||
| CVE-2019-18858 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2019-11-22 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. | |||||
| CVE-2019-16265 | 1 Codesys | 2 Codesys, Eni Server | 2019-10-28 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2.3 ENI server up to V3.2.2.24 has a Buffer Overflow. | |||||
| CVE-2018-10612 | 1 Codesys | 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. | |||||
| CVE-2017-6025 | 1 Codesys | 1 Web Server | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code. | |||||
| CVE-2017-6027 | 1 Codesys | 1 Web Server | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution. | |||||