Search
Total
24 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-38823 | 1 Tenda | 8 Ac18, Ac18 Firmware, Ac19 and 5 more | 2023-11-28 | N/A | 9.8 CRITICAL |
| Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd. | |||||
| CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2023-08-10 | N/A | 9.8 CRITICAL |
| Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | |||||
| CVE-2023-38936 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2023-08-10 | N/A | 9.8 CRITICAL |
| Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
| CVE-2023-38935 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac1206 and 7 more | 2023-08-10 | N/A | 9.8 CRITICAL |
| Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. | |||||
| CVE-2023-38933 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2023-08-10 | N/A | 9.8 CRITICAL |
| Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | |||||
| CVE-2023-38930 | 1 Tenda | 10 Ac5, Ac5 Firmware, Ac7 and 7 more | 2023-08-09 | N/A | 9.8 CRITICAL |
| Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. | |||||
| CVE-2022-25427 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function. | |||||
| CVE-2022-25434 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function. | |||||
| CVE-2022-25433 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function. | |||||
| CVE-2022-25431 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function. | |||||
| CVE-2022-25429 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function. | |||||
| CVE-2022-25428 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function. | |||||
| CVE-2022-36273 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | N/A | 9.8 CRITICAL |
| Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg. | |||||
| CVE-2022-25441 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function. | |||||
| CVE-2022-25440 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function. | |||||
| CVE-2022-25439 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function. | |||||
| CVE-2022-25438 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function. | |||||
| CVE-2022-25437 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function. | |||||
| CVE-2022-25435 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
| Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function. | |||||
| CVE-2022-28560 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-05-11 | 10.0 HIGH | 9.8 CRITICAL |
| There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload | |||||
| CVE-2020-26728 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-02-22 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request. | |||||
| CVE-2018-18729 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac15 and 7 more | 2019-10-03 | 9.0 HIGH | 9.8 CRITICAL |
| An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow. | |||||
| CVE-2018-18728 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2019-10-03 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request. | |||||
| CVE-2018-14558 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac7 and 3 more | 2019-10-03 | 10.0 HIGH | 9.8 CRITICAL |
| An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. | |||||
