CVE-2023-49409 1 Tenda 2 Ax3, Ax3 Firmware 2023-12-09 N/A 9.8 CRITICAL
Tenda AX3 V16.03.12.11 was discovered to contain a Command Execution vulnerability via the function /goform/telnet.
CVE-2023-49040 1 Tenda 2 Ax1803, Ax1803 Firmware 2023-12-01 N/A 9.8 CRITICAL
An issue in Tneda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the adslPwd parameter in the form_fast_setting_internet_set function.
CVE-2023-49042 1 Tenda 2 Ax1803, Ax1803 Firmware 2023-12-01 N/A 9.8 CRITICAL
Heap Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the schedStartTime parameter or the schedEndTime parameter in the function setSchedWifi.
CVE-2023-49044 1 Tenda 2 Ax1803, Ax1803 Firmware 2023-12-01 N/A 9.8 CRITICAL
Stack Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the ssid parameter in the function form_fast_setting_wifi_set.
CVE-2023-45480 1 Tenda 2 Ac10, Ac10 Firmware 2023-12-01 N/A 9.8 CRITICAL
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
CVE-2023-45479 1 Tenda 2 Ac10, Ac10 Firmware 2023-12-01 N/A 9.8 CRITICAL
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098.
CVE-2023-45482 1 Tenda 2 Ac10, Ac10 Firmware 2023-12-01 N/A 9.8 CRITICAL
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
CVE-2023-45481 1 Tenda 2 Ac10, Ac10 Firmware 2023-12-01 N/A 9.8 CRITICAL
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
CVE-2023-45483 1 Tenda 2 Ac10, Ac10 Firmware 2023-12-01 N/A 9.8 CRITICAL
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time.
CVE-2023-45484 1 Tenda 2 Ac10, Ac10 Firmware 2023-12-01 N/A 9.8 CRITICAL
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic.
CVE-2023-49043 1 Tenda 2 Ax1803, Ax1803 Firmware 2023-12-01 N/A 9.8 CRITICAL
Buffer Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the wpapsk_crypto parameter in the function fromSetWirelessRepeat.
CVE-2023-49046 1 Tenda 2 Ax1803, Ax1803 Firmware 2023-12-01 N/A 9.8 CRITICAL
Stack Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the devName parameter in the function formAddMacfilterRule.
CVE-2023-38823 1 Tenda 8 Ac18, Ac18 Firmware, Ac19 and 5 more 2023-11-28 N/A 9.8 CRITICAL
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
CVE-2023-47456 1 Tenda 2 Ax1806, Ax1806 Firmware 2023-11-14 N/A 9.1 CRITICAL
Tenda AX1806 V1.0.0.1 contains a stack overflow vulnerability in function sub_455D4, called by function fromSetWirelessRepeat.
CVE-2023-47455 1 Tenda 2 Ax1806, Ax1806 Firmware 2023-11-14 N/A 9.1 CRITICAL
Tenda AX1806 V1.0.0.1 contains a heap overflow vulnerability in setSchedWifi function, in which the src and v12 are directly obtained from http request parameter schedStartTime and schedEndTime without checking their size.
CVE-2023-40846 1 Tenda 2 Ac6, Ac6 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998.
CVE-2023-40901 1 Tenda 2 Ac10v4, Ac10v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
CVE-2023-40900 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
CVE-2023-40899 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
CVE-2023-40898 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.
CVE-2023-40897 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.
CVE-2023-40895 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-40896 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
CVE-2023-40894 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
CVE-2023-40893 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-40892 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.
CVE-2023-40891 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
CVE-2023-40799 1 Tenda 2 Ac23, Ac23 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC23 Vv16.03.07.45_cn is vulnerable to Buffer Overflow via sub_450A4C function.
CVE-2023-39673 1 Tenda 2 Ac15, Ac15 Firmware 2023-08-23 N/A 9.8 CRITICAL
Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34().
CVE-2023-39670 1 Tenda 2 Ac6, Ac6 Firmware 2023-08-23 N/A 9.8 CRITICAL
Tenda AC6 _US_AC6V1.0BR_V15.03.05.16 was discovered to contain a buffer overflow via the function fgets.
CVE-2023-39672 1 Tenda 2 Wh450a, Wh450a Firmware 2023-08-23 N/A 9.8 CRITICAL
Tenda WH450 v1.0.0.18 was discovered to contain a buffer overflow via the function fgets.
CVE-2023-38937 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2023-08-10 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
CVE-2023-38936 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2023-08-10 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-38935 1 Tenda 10 Ac10, Ac10 Firmware, Ac1206 and 7 more 2023-08-10 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
CVE-2023-38933 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2023-08-10 N/A 9.8 CRITICAL
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-38931 1 Tenda 16 Ac10, Ac10 Firmware, Ac1206 and 13 more 2023-08-10 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
CVE-2023-38939 1 Tenda 4 F1202, F1202 Firmware, Fh1202 and 1 more 2023-08-09 N/A 9.8 CRITICAL
Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function.
CVE-2023-38938 1 Tenda 8 F1202, F1202 Firmware, Fh1202 and 5 more 2023-08-09 N/A 9.8 CRITICAL
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im.
CVE-2023-38934 1 Tenda 6 F1203, F1203 Firmware, Fh1203 and 3 more 2023-08-09 N/A 9.8 CRITICAL
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-38940 1 Tenda 6 F1203, F1203 Firmware, Fh1203 and 3 more 2023-08-09 N/A 9.8 CRITICAL
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-38930 1 Tenda 10 Ac5, Ac5 Firmware, Ac7 and 7 more 2023-08-09 N/A 9.8 CRITICAL
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-38932 1 Tenda 8 F1202, F1202 Firmware, Fh1202 and 5 more 2023-08-09 N/A 9.8 CRITICAL
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function.
CVE-2023-38929 1 Tenda 2 4g300, 4g300 Firmware 2023-08-09 N/A 9.8 CRITICAL
Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer.
CVE-2022-26536 1 Tenda 2 M3, M3 Firmware 2023-08-08 10.0 HIGH 9.8 CRITICAL
Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/setFixTools.
CVE-2022-28557 1 Tenda 2 Ac15, Ac15 Firmware 2023-08-08 7.5 HIGH 9.8 CRITICAL
There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution
CVE-2022-46538 1 Tenda 2 F1203, F1203 Firmware 2023-08-08 N/A 9.8 CRITICAL
Tenda F1203 V2.0.1.6 was discovered to contain a command injection vulnerability via the mac parameter at /goform/WriteFacMac.
CVE-2022-45506 1 Tenda 2 W30e, W30e Firmware 2023-08-08 N/A 9.8 CRITICAL
Tenda W30E v1.0.1.25(633) was discovered to contain a command injection vulnerability via the fileNameMit parameter at /goform/delFileName.
CVE-2022-45497 1 Tenda 2 W6-s, W6-s Firmware 2023-08-08 N/A 9.8 CRITICAL
Tenda W6-S v1.0.0.4(510) was discovered to contain a command injection vulnerability in the tpi_get_ping_output function at /goform/exeCommand.
CVE-2022-37810 1 Tenda 2 Ac1206, Ac1206 Firmware 2023-08-08 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
CVE-2022-36273 1 Tenda 2 Ac9, Ac9 Firmware 2023-08-08 N/A 9.8 CRITICAL
Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg.