Filtered by vendor Schneider-electric
Subscribe
Search
Total
111 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-22704 | 1 Schneider-electric | 10 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 7 more | 2021-09-20 | 6.4 MEDIUM | 9.1 CRITICAL |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP. | |||||
| CVE-2021-22707 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 10.0 HIGH | 9.8 CRITICAL |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges. | |||||
| CVE-2021-22727 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized access to the charging station web server | |||||
| CVE-2021-22772 | 1 Schneider-electric | 6 T200e, T200e Firmware, T200i and 3 more | 2021-07-28 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is bypassed. | |||||
| CVE-2021-22729 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 10.0 HIGH | 9.8 CRITICAL |
| A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server. | |||||
| CVE-2021-22730 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 10.0 HIGH | 9.8 CRITICAL |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server. | |||||
| CVE-2021-22779 | 1 Schneider-electric | 61 Ecostruxure Control Expert, Ecostruxure Process Expert, Modicon M340 Bmxp341000 and 58 more | 2021-07-26 | 6.4 MEDIUM | 9.1 CRITICAL |
| Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller. | |||||
| CVE-2021-22763 | 1 Schneider-electric | 10 Powerlogic Pm5560, Powerlogic Pm5560 Firmware, Powerlogic Pm5561 and 7 more | 2021-06-23 | 10.0 HIGH | 9.8 CRITICAL |
| A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device. | |||||
| CVE-2017-9629 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2021-06-07 | 10.0 HIGH | 9.8 CRITICAL |
| A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account. | |||||
| CVE-2017-5178 | 1 Schneider-electric | 3 Tableau Desktop, Tableau Server, Wonderware Intelligence | 2021-06-04 | 10.0 HIGH | 9.8 CRITICAL |
| An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access. | |||||
| CVE-2021-22737 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2021-06-04 | 5.0 MEDIUM | 9.8 CRITICAL |
| Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack. | |||||
| CVE-2021-22738 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2021-06-03 | 5.0 MEDIUM | 9.8 CRITICAL |
| Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access when credentials are discovered after a brute force attack. | |||||
| CVE-2019-6814 | 1 Schneider-electric | 14 Net5500, Net5500 Firmware, Net5501 and 11 more | 2021-04-19 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI. | |||||
| CVE-2020-28221 | 1 Schneider-electric | 42 Ecostruxure Operator Terminal Expert, Gp-4104g, Gp-4104w and 39 more | 2021-02-12 | 9.3 HIGH | 9.8 CRITICAL |
| A CWE-20: Improper Input Validation vulnerability exists in EcoStruxureâ„¢ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI. | |||||
| CVE-2020-7540 | 1 Schneider-electric | 46 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 43 more | 2020-12-14 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests. | |||||
| CVE-2020-28215 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently. | |||||
| CVE-2020-7561 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-11 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-284: Improper Access Control vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted. | |||||
| CVE-2020-7548 | 1 Schneider-electric | 14 Acti9 Powertag Link, Acti9 Powertag Link Firmware, Acti9 Powertag Link Hd and 11 more | 2020-12-08 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login. | |||||
| CVE-2020-7521 | 1 Schneider-electric | 1 Apc Easy Ups Online Software | 2020-09-04 | 7.5 HIGH | 9.8 CRITICAL |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories. | |||||
| CVE-2020-7522 | 1 Schneider-electric | 1 Apc Easy Ups Online Software | 2020-09-04 | 7.5 HIGH | 9.8 CRITICAL |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `SoundUploadServlet` which may lead to uploading executable files to non-specified directories. | |||||
| CVE-2019-6815 | 1 Schneider-electric | 2 Modicon Quantum, Modicon Quantum Firmware | 2020-08-24 | 6.4 MEDIUM | 9.1 CRITICAL |
| In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol. | |||||
| CVE-2020-7485 | 2 Microsoft, Schneider-electric | 4 Windows 7, Windows Nt, Windows Xp and 1 more | 2020-07-30 | 7.5 HIGH | 9.8 CRITICAL |
| **VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy support account in the TriStation software version v4.9.0 and earlier could cause improper access to the TriStation host machine. This was addressed in TriStation version v4.9.1 and v4.10.1 released on May 30, 2013.1 | |||||
| CVE-2012-0931 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2020-07-23 | 7.5 HIGH | 9.8 CRITICAL |
| Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors. | |||||
| CVE-2020-7497 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2020-06-19 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts. | |||||
| CVE-2020-7512 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-19 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to exploit the component. | |||||
| CVE-2020-7508 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-17 | 5.0 MEDIUM | 9.8 CRITICAL |
| A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to gain full access by brute force. | |||||
| CVE-2020-7480 | 1 Schneider-electric | 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more | 2020-03-25 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data. | |||||
| CVE-2019-6823 | 1 Schneider-electric | 1 Proclima | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0. | |||||
| CVE-2019-6824 | 1 Schneider-electric | 1 Proclima | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0. | |||||
| CVE-2019-6840 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed. | |||||
| CVE-2019-6837 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2019-10-09 | 6.4 MEDIUM | 9.1 CRITICAL |
| A Server-Side Request Forgery (SSRF): CWE-918 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could cause server configuration data to be exposed when an attacker modifies a URL. | |||||
| CVE-2018-7820 | 1 Schneider-electric | 8 Ap9630, Ap9630 Firmware, Ap9631 and 5 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled. | |||||
| CVE-2017-6034 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download. | |||||
| CVE-2017-13997 | 1 Schneider-electric | 2 Wonderware Indusoft Web Studio, Wonderware Intouch | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. | |||||
| CVE-2018-7243 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2019-10-03 | 10.0 HIGH | 9.8 CRITICAL |
| An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system. | |||||
| CVE-2018-7245 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2019-10-03 | 6.4 MEDIUM | 9.1 CRITICAL |
| An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization. | |||||
| CVE-2018-7246 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2019-10-03 | 5.0 MEDIUM | 9.8 CRITICAL |
| A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext | |||||
| CVE-2018-7785 | 1 Schneider-electric | 1 U.motion Builder | 2019-10-03 | 7.5 HIGH | 9.8 CRITICAL |
| In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass. | |||||
| CVE-2018-7811 | 1 Schneider-electric | 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more | 2019-10-02 | 5.0 MEDIUM | 9.8 CRITICAL |
| An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the change password function of the web server | |||||
| CVE-2018-7784 | 1 Schneider-electric | 1 U.motion | 2019-09-30 | 7.5 HIGH | 9.8 CRITICAL |
| In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application. | |||||
| CVE-2018-1126 | 5 Canonical, Debian, Procps-ng Project and 2 more | 10 Ubuntu Linux, Debian Linux, Procps-ng and 7 more | 2019-07-30 | 7.5 HIGH | 9.8 CRITICAL |
| procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124. | |||||
| CVE-2018-7780 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2019-05-24 | 7.5 HIGH | 9.8 CRITICAL |
| In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set". | |||||
| CVE-2019-6816 | 1 Schneider-electric | 2 Modicon Quantum, Modicon Quantum Firmware | 2019-05-23 | 6.4 MEDIUM | 9.1 CRITICAL |
| In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol. | |||||
| CVE-2018-7841 | 1 Schneider-electric | 1 U.motion Builder | 2019-05-23 | 7.5 HIGH | 9.8 CRITICAL |
| A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered. | |||||
| CVE-2018-7800 | 1 Schneider-electric | 2 Evlink Parking, Evlink Parking Firmware | 2019-02-28 | 10.0 HIGH | 9.8 CRITICAL |
| A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device. | |||||
| CVE-2018-7836 | 1 Schneider-electric | 1 Iiot Monitor | 2019-02-06 | 7.5 HIGH | 9.8 CRITICAL |
| An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files. | |||||
| CVE-2018-7809 | 1 Schneider-electric | 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more | 2018-12-28 | 6.4 MEDIUM | 9.8 CRITICAL |
| An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the password delete function of the web server. | |||||
| CVE-2018-7242 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2018-12-05 | 5.0 MEDIUM | 9.8 CRITICAL |
| Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks. | |||||
| CVE-2018-7241 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2018-12-05 | 10.0 HIGH | 9.8 CRITICAL |
| Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. | |||||
| CVE-2018-7778 | 1 Schneider-electric | 2 Evlink Charging Station, Evlink Charging Station Firmware | 2018-09-05 | 7.5 HIGH | 9.8 CRITICAL |
| In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users. | |||||