Search
Total
18 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-6339 | 1 Google | 2 Nest Wifi Pro, Nest Wifi Pro Firmware | 2024-01-09 | N/A | 9.8 CRITICAL |
| Google Nest WiFi Pro root code-execution & user-data compromise | |||||
| CVE-2021-27779 | 1 Hcltech | 1 Versionvault Express | 2022-06-08 | 6.4 MEDIUM | 9.1 CRITICAL |
| VersionVault Express exposes sensitive information that an attacker can use to impersonate the server or eavesdrop on communications with the server. | |||||
| CVE-2019-17218 | 1 Vzug | 2 Combi-stream Mslq, Combi-stream Mslq Firmware | 2021-07-21 | 5.0 MEDIUM | 9.1 CRITICAL |
| An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05. By default, the communication to the web service is unencrypted via http. An attacker is able to intercept and sniff communication to the web service. | |||||
| CVE-2019-16672 | 1 Weidmueller | 80 Ie-sw-pl08m-6tx-2sc, Ie-sw-pl08m-6tx-2sc Firmware, Ie-sw-pl08m-6tx-2scs and 77 more | 2021-07-21 | 5.0 MEDIUM | 9.8 CRITICAL |
| An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext. | |||||
| CVE-2017-7406 | 1 Dlink | 1 Dir-615 | 2021-04-23 | 5.0 MEDIUM | 9.8 CRITICAL |
| The D-Link DIR-615 device before v20.12PTb04 doesn't use SSL for any of the authenticated pages. Also, it doesn't allow the user to generate his own SSL Certificate. An attacker can simply monitor network traffic to steal a user's credentials and/or credentials of users being added while sniffing the traffic. | |||||
| CVE-2018-16879 | 1 Redhat | 1 Ansible Tower | 2020-12-04 | 7.5 HIGH | 9.8 CRITICAL |
| Ansible Tower before version 3.3.3 does not set a secure channel as it is using the default insecure configuration channel settings for messaging celery workers from RabbitMQ. This could lead in data leak of sensitive information such as passwords as well as denial of service attacks by deleting projects or inventory files. | |||||
| CVE-2018-13992 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2020-08-24 | 5.0 MEDIUM | 9.8 CRITICAL |
| The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 allows for plaintext transmission (HTTP) of user credentials by default. | |||||
| CVE-2019-12924 | 1 Mailenable | 1 Mailenable | 2020-08-24 | 5.0 MEDIUM | 9.8 CRITICAL |
| MailEnable Enterprise Premium 10.23 was vulnerable to XML External Entity Injection (XXE) attacks that could be exploited by an unauthenticated user. It was possible for an attacker to use a vulnerability in the configuration of the XML processor to read any file on the host system. Because all credentials were stored in a cleartext file, it was possible to steal all users' credentials (including the highest privileged users). | |||||
| CVE-2018-10698 | 1 Moxa | 2 Awk-3121, Awk-3121 Firmware | 2020-08-24 | 10.0 HIGH | 9.8 CRITICAL |
| An issue was discovered on Moxa AWK-3121 1.14 devices. The device enables an unencrypted TELNET service by default. This allows an attacker who has been able to gain an MITM position to easily sniff the traffic between the device and the user. Also an attacker can easily connect to the TELNET daemon using the default credentials if they have not been changed by the user. | |||||
| CVE-2019-11367 | 1 Auo | 1 Solar Data Recorder | 2020-08-24 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered in AUO Solar Data Recorder before 1.3.0. The web portal uses HTTP Basic Authentication and provides the account and password in the WWW-Authenticate attribute. By using this account and password, anyone can login successfully. | |||||
| CVE-2019-11523 | 1 Anviz | 2 M3, M3 Firmware | 2020-08-24 | 7.5 HIGH | 9.8 CRITICAL |
| Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the "open door" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address). | |||||
| CVE-2018-7498 | 1 Philips | 2 Alice 6, Alice 6 Firmware | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| In Philips Alice 6 System version R8.0.2 or prior, the lack of proper data encryption passes up the guarantees of confidentiality, integrity, and accountability that properly implemented encryption conveys. | |||||
| CVE-2018-17915 | 1 Xiongmaitech | 1 Xmeye P2p Cloud Server | 2019-10-09 | 6.4 MEDIUM | 9.8 CRITICAL |
| All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server do not encrypt all device communication. This includes the XMeye service and firmware update communication. This could allow an attacker to eavesdrop on video feeds, steal XMeye login credentials, or impersonate the update server with malicious update code. | |||||
| CVE-2018-10612 | 1 Codesys | 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. | |||||
| CVE-2017-9632 | 1 Pdqinc | 22 Laserjet, Laserjet Firmware, Laserwash 360 and 19 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A Missing Encryption of Sensitive Data issue was discovered in PDQ Manufacturing LaserWash G5 and G5 S Series all versions, LaserWash M5, all versions, LaserWash 360 and 360 Plus, all versions, LaserWash AutoXpress and AutoExpress Plus, all versions, LaserJet, all versions, ProTouch Tandem, all versions, ProTouch ICON, all versions, and ProTouch AutoGloss, all versions. The username and password are transmitted insecurely. | |||||
| CVE-2017-3198 | 1 Gigabyte | 4 Gb-bsi7h-6500, Gb-bsi7h-6500 Firmware, Gb-bxi7-5775 and 1 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| GIGABYTE BRIX UEFI firmware does not cryptographically validate images prior to updating the system firmware. Additionally, the firmware updates are served over HTTP. An attacker can make arbitrary modifications to firmware images without being detected. | |||||
| CVE-2018-20100 | 1 August | 2 August Connect, August Connect Firmware | 2019-10-03 | 5.0 MEDIUM | 9.8 CRITICAL |
| An issue was discovered on August Connect devices. Insecure data transfer between the August app and August Connect during configuration allows attackers to discover home Wi-Fi credentials. This data transfer uses an unencrypted access point for these credentials, and passes them in an HTTP POST, using the AugustWifiDevice class, with data encrypted with a fixed key found obfuscated in the app. | |||||
| CVE-2017-9854 | 1 Sma | 78 Sunny Boy 1.5, Sunny Boy 1.5 Firmware, Sunny Boy 2.5 and 75 more | 2019-10-03 | 5.0 MEDIUM | 9.8 CRITICAL |
| ** DISPUTED ** An issue was discovered in SMA Solar Technology products. By sniffing for specific packets on the localhost, plaintext passwords can be obtained as they are typed into Sunny Explorer by the user. These passwords can then be used to compromise the overall device. NOTE: the vendor reports that exploitation likelihood is low because these packets are usually sent only once during installation. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected. | |||||