Search
Total
14 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-1886 | 1 Phpmyfaq | 1 Phpmyfaq | 2023-12-18 | N/A | 9.8 CRITICAL |
| Authentication Bypass by Capture-replay in GitHub repository thorsten/phpmyfaq prior to 3.1.12. | |||||
| CVE-2022-45789 | 1 Schneider-electric | 72 Ecostruxure Control Expert, Ecostruxure Process Expert, Modicon M340 Bmxp341000 and 69 more | 2023-08-09 | N/A | 9.8 CRITICAL |
| A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions) | |||||
| CVE-2021-22640 | 1 Ovarro | 15 Tbox Lt2-530, Tbox Lt2-530 Firmware, Tbox Lt2-532 and 12 more | 2023-08-08 | N/A | 9.8 CRITICAL |
| An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks. | |||||
| CVE-2022-29334 | 1 H Project | 1 H | 2023-08-08 | 7.5 HIGH | 9.8 CRITICAL |
| An issue in H v1.0 allows attackers to bypass authentication via a session replay attack. | |||||
| CVE-2022-22806 | 1 Schneider-electric | 16 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 13 more | 2022-05-12 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior) | |||||
| CVE-2018-7790 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 7.5 HIGH | 9.8 CRITICAL |
| An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC. | |||||
| CVE-2021-41030 | 1 Fortinet | 1 Forticlient Enterprise Management Server | 2021-12-10 | 6.4 MEDIUM | 9.1 CRITICAL |
| An authentication bypass by capture-replay vulnerability [CWE-294] in FortiClient EMS versions 7.0.1 and below and 6.4.4 and below may allow an unauthenticated attacker to impersonate an existing user by intercepting and re-using valid SAML authentication messages. | |||||
| CVE-2021-38459 | 1 Auvesy | 1 Versiondog | 2021-10-27 | 7.5 HIGH | 9.8 CRITICAL |
| The data of a network capture of the initial handshake phase can be used to authenticate at a SYSDBA level. If a specific .exe is not restarted often, it is possible to access the needed handshake packets between admin/client connections. Using the SYSDBA permission, an attacker can change user passwords or delete the database. | |||||
| CVE-2020-35551 | 1 Google | 1 Android | 2020-12-18 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered on Samsung mobile devices with O(8.x), P(9.0), and Q(10.0) (Exynos chipsets) software. They allow attackers to conduct RPMB state-change attacks because an unauthorized RPMB write operation can be replayed, a related issue to CVE-2020-13799. The Samsung ID is SVE-2020-18100 (December 2020). | |||||
| CVE-2018-17932 | 1 Juuko | 2 K-800, K-800 Firmware | 2020-11-12 | 10.0 HIGH | 9.8 CRITICAL |
| JUUKO K-800 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.) is vulnerable to a replay attack and command forgery, which could allow attackers to replay commands, control the device, view commands, or cause the device to stop running. | |||||
| CVE-2018-19025 | 1 Juuko | 2 K-808, K-808 Firmware | 2020-11-12 | 10.0 HIGH | 9.8 CRITICAL |
| In JUUKO K-808, an attacker could specially craft a packet that encodes an arbitrary command, which could be executed on the K-808 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.). | |||||
| CVE-2019-18226 | 1 Honeywell | 128 H2w2gr1, H2w2gr1 Firmware, H2w2pc1m and 125 more | 2020-09-29 | 7.5 HIGH | 9.8 CRITICAL |
| Honeywell equIP series and Performance series IP cameras and recorders, A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products. | |||||
| CVE-2018-17903 | 1 Sagaradio | 2 Saga1-l8b, Saga1-l8b Firmware | 2020-09-18 | 6.4 MEDIUM | 9.1 CRITICAL |
| SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to a replay attack and command forgery. | |||||
| CVE-2020-6972 | 1 Honeywell | 1 Notifier Webserver | 2020-03-27 | 6.4 MEDIUM | 9.1 CRITICAL |
| In Notifier Web Server (NWS) Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser. | |||||